What was found
AT HMV, STRINGER 15R FOUND CRACKED AT AFT SIDE OF RT WING LEADING EDGE ICE LIGHT HOUSING AT FS 720C. REPAIRED PER SRM 53-10-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT HMV, STRINGER 15R FOUND CRACKED AT AFT SIDE OF RT WING LEADING EDGE ICE LIGHT HOUSING AT FS 720C. REPAIRED PER SRM 53-10-3.