What was found
ANGLE OUT AT STA 957 LT SIDE OF FUSELAGE OVER STA 18A. FAIRING ATTACH WEB CRACKED REF EO 4-60175-3. STARTED FABRICATING REPAIR AS PER M/M 53-12-0 FIG 1. FABRICATED REPAIR PER M/M 53-12-0. HEAT TREATED REPAIR PORTS PER PS 900-4-1 NR 1. OK TO INST SPLICE ANGLES. INSTALLED SPLICE REPAIR IAW M/M, FABRICATED WEB PER SRM 51-00. INSTALLED WEB PER SRM 51-00.