What was found
DURING CRUISE FLIGHT ATTENDANT REPORTED AN ELECTRICAL ODOR IN CABIN AT SEAT ROWS 17&18. FLIGHT ATTENDANT TURNED OFF CABIN LIGHTS AND RECIRCULATION FANS WERE TURNED OFF. SMELL DISAPPEARED AND NO VISIBLE SMOKE WAS NOTED IN THE CABIN DURING THIS PERIOD. EXAMINED WIRING UNDER PASS SERVICE UNITS AND CEILING PANELS FROM ROWS 16-19. NO TROUBLE FOUND. CHECKED AIR CONDITIONING BAYS AND RECIRCULATION FANS AREA. NO OVERHEATING OR SMELL NOTED. RAN BOTH ENGINES TO POWER WITH BOTH PACKS RUNNING, ALL CABIN LIGHTS ON, VIDEO SYS ON, AND OVEN/COFFEEMAKERS ON. NO TROUBLE FOUND.