As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOORBEAM CORRODED FS 344, RBL 14 TO LBL 48. REMOVED CORROSION PER SRM 51-10-6 AREA OUT OF LIMITS PER SRM 53-10-1. BEGAN REMOVING T-CAP. DRILLED UP REPLACMENT T-CAP PER M/M 53-21-0 FIG 803. OK TO INSTALL. STARTED INSTALLATION OF T-CAP PER M/M 53-21-0 FIG 803. CHEMICALLY TREATED PER 900-2 NR 5.