What was found
ON PRE-FLIGHT, FOUND EMERGENCY TRACK LIGHTS INOP AT SEAT ROWS 10 TO 15, FOUND SHORTED WIRES IN TRACK. REPAIRED WIRES, OPERATION NORMAL. ALSO, HAD FWD GALLEY AND BOTH AFT GALLEY DOORS EMERGENCY LIGHTS INOP. REPLACED FWD GALLEY LIGHT ASSEMBLY AND LENS. FOUND LEADS SHORTED TO GROUND AT AFT DOOR LIGHTS, REPAIRED WIRES OPERATION NORMAL.