As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
NOSE LANDING GEAR HORIZONTAL PRESSURE DECK WAS FOUND WITH CORROSION AT FS 394 AND LBL 27 EXTENDING .042 DEEP. CUT OUT RESULTED IN HOLE SIZED 2.0 (I/B-O/B) BY 3.0 (FWD-AFT). THE PANEL IS M/F LS10328 AND IS .075 THICK LOCALLY. REPAIRED PER ERA 361052-14 REV A.