What was found
FOUND ON W-1 LETTER CHECK, VERTICAL STAB COMPOSITE T/E PANEL DELAMINATED 2 PLACES LEFT SIDE, 1 PLACE RIGHT SIDE. REPAIRED PER SRM 55-30-3 FIG 3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND ON W-1 LETTER CHECK, VERTICAL STAB COMPOSITE T/E PANEL DELAMINATED 2 PLACES LEFT SIDE, 1 PLACE RIGHT SIDE. REPAIRED PER SRM 55-30-3 FIG 3.