A/C 324 FLT 1500, JUST PRIOR TO TOUCHDOWN MASTER CAUTION LIGHT CAME ON FOR A-SYS HYD LEAK. WHILE TURNING OFF RUNWAY A-SYS HYD QUANTITY WENT TO ZERO, FLAP LEVER WAS LEFT AT 30 DEGREES TO AGREE WITH FLAPS. FOUND HYD PRESSURE LINE LEAKING ON LEFT LANDING GEAR ACTUATOR. REPLACED LINE.