What was found
RIGHT ENG HYD PUMP EICAS MSG AND RT ENG HYD PRESS LIGHT ILLUM ON TAKEOFF. RIGHT ENG HYD PUMP SWITCH TURNED OFF. FOUND PYLON SUPPLY LINE B-NUT LOOSE, SECURED SAME. MOTORED ENG. GOOD PRESSURE, NO LEAKS.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RIGHT ENG HYD PUMP EICAS MSG AND RT ENG HYD PRESS LIGHT ILLUM ON TAKEOFF. RIGHT ENG HYD PUMP SWITCH TURNED OFF. FOUND PYLON SUPPLY LINE B-NUT LOOSE, SECURED SAME. MOTORED ENG. GOOD PRESSURE, NO LEAKS.