Service difficulty report · Controller · Boeing 757232

Difficulty date
October 26, 2003
Submitted
December 29, 2003
Operation
Air carrier
Aircraft
N687DL
Make and model
Boeing 757232
Aircraft serial
27586
Aircraft time
18,512 hours, 8,607 cycles
Part
Controller
Part number
216001221
Condition
Malfunctioned
Location
A/C Bay
Stage of operation
CR
How discovered
O
Nature of condition
M
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

LT PACK WENT FULL HOT UNCONTROLLABLE. DUCT TEMPS WERE 120 DEGREES WITH PACK CONTROLLER IN AUTO AND STBY. SELECTED PACK CONTROLLER TO COLD AND DECREASED DUCT TEMP. INSPECTED SENSORS, RAN BITE ON TEMP CONTROLLER, NO FAULTS. REPLACED PACK TEMP VALVE, ZONE TEMP CONTROLLER AND OVERHEAD CONTROL PANEL. SYSTEM CHECKS GOOD.