As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
NR 915 HMV-3 VISIT INSPECTION OPN 5876, HARDWARE CORRODED ON CABLE FOR MANUAL EMERGENCY RELEASE CABLE LT SIDE OF FUSELAGE BETWEEN OVERWING EXITS STA 984-996 STRINGER 17L. REMOVED SAFETY WIRE, CLEANED AREA OF CORROSION. OK TO INSTALL NEW HARDWARE. INSTALLED NEW HARDWARE AND RESAFTIED. IPC ITEMS NR 150/155/160/173/175 REPLACED. P/N'S MS24665-132/MS20392-2C17/BACW10P270L/AN960-10/MS35650-302/MS35812-1.