What was found
ON INSPECTION FOUND EMERGENCY LIGHTS INOP ON AFT RIGHT LAVATORY. REPAIRED THREE BROKEN WIRES UNDER AISLE CARPET AT RT AFT LAVATORY PER WSPM. OPN OF LIGHTS NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ON INSPECTION FOUND EMERGENCY LIGHTS INOP ON AFT RIGHT LAVATORY. REPAIRED THREE BROKEN WIRES UNDER AISLE CARPET AT RT AFT LAVATORY PER WSPM. OPN OF LIGHTS NORMAL.