What was found
IR- ON L/O FOUND EMERGENCY EXIT SIGN ABOVE 4L DOOR INOP. RELAMPED, NO HELP. REMOVED AND REPLACED SIGN, NO HELP. INSTALLED ORG. T/S PER WDM 33-51-11, FOUND PWR SUPPLY M737 FUSE BURNED OUT. REPLACED FUSE, OPS CK OK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
IR- ON L/O FOUND EMERGENCY EXIT SIGN ABOVE 4L DOOR INOP. RELAMPED, NO HELP. REMOVED AND REPLACED SIGN, NO HELP. INSTALLED ORG. T/S PER WDM 33-51-11, FOUND PWR SUPPLY M737 FUSE BURNED OUT. REPLACED FUSE, OPS CK OK.