What was found
NUMBER 2 PYLON SIDE LINK ATTACH FITTING HOLE NR 3 WAS FOUND MISALIGNED WHILE ACCOMPLISHING DELTAS EO 6-70332-3 COVERING SB 757-54-0034. A TAPERED RADIUS FILLER WAS INSTALLED PER ANAMOC TO AD 2003-18-05.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NUMBER 2 PYLON SIDE LINK ATTACH FITTING HOLE NR 3 WAS FOUND MISALIGNED WHILE ACCOMPLISHING DELTAS EO 6-70332-3 COVERING SB 757-54-0034. A TAPERED RADIUS FILLER WAS INSTALLED PER ANAMOC TO AD 2003-18-05.