What was found
DURING ACCOMPLISHMENT OF THE SIP MOD, S/B 757-54-0034 REV 1, THE DIAGONAL BRACE LOWER/FWD I/B LUG WAS INADVERTENTLY OVERSIZED TO 2.003" INSTEAD OF THE REQUIRED 2.000" MAXIMUM. AN OVERSIZED BUSHING WAS INSTALLED. AD 2003-18-05 APPLIES.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING ACCOMPLISHMENT OF THE SIP MOD, S/B 757-54-0034 REV 1, THE DIAGONAL BRACE LOWER/FWD I/B LUG WAS INADVERTENTLY OVERSIZED TO 2.003" INSTEAD OF THE REQUIRED 2.000" MAXIMUM. AN OVERSIZED BUSHING WAS INSTALLED. AD 2003-18-05 APPLIES.