What was found
CORROSION AROUND NUTPLATES BS 1530 RBL 22 COMMON TO FLOOR TO SIDE WALL SPLICE LOWER SURFACE OF SPLICE, BULDGED. REPLACED SPLICE IAW 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION AROUND NUTPLATES BS 1530 RBL 22 COMMON TO FLOOR TO SIDE WALL SPLICE LOWER SURFACE OF SPLICE, BULDGED. REPLACED SPLICE IAW 51-40-02.