What was found
2 ELONGATED HOLES MAIN CABIN AFT DECK PLATE STA 1685 RBL 51 FWD OF GALLEY MOUNT AREA. REPLACED GALLEY MOUNT FITTING AND FLOOR SUPPORT PER SRM 51-40-05 DURING HMV AT SAA ON NRC 126708.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
2 ELONGATED HOLES MAIN CABIN AFT DECK PLATE STA 1685 RBL 51 FWD OF GALLEY MOUNT AREA. REPLACED GALLEY MOUNT FITTING AND FLOOR SUPPORT PER SRM 51-40-05 DURING HMV AT SAA ON NRC 126708.