What was found
EXTERIOR SKIN HAD TWO SMALL HOLES CAUSED BY HAIL IN DFW. BOTH HOLES WHERE LESS THAN 2 INCHES IN DIAMETER. DAMAGE WAS REPAIRED IN ACCORDANCED WITH SRM 57-70-01 WITH REF TO 51-70-17. FOUND DURING SHOP VISIT FOR NR 8 SPOILER PANEL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
EXTERIOR SKIN HAD TWO SMALL HOLES CAUSED BY HAIL IN DFW. BOTH HOLES WHERE LESS THAN 2 INCHES IN DIAMETER. DAMAGE WAS REPAIRED IN ACCORDANCED WITH SRM 57-70-01 WITH REF TO 51-70-17. FOUND DURING SHOP VISIT FOR NR 8 SPOILER PANEL.