As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
STRONG ELECTRICAL ODOR THROUGHOUT A/C. EICAS STATUS MSG FWD EQUIP DET 2. EQUIP COOLING TEST. FUEL QUANTITY BITE. STANDBY INVERTER. DIVERTED TO KSAV. DETERMINED THE SOURCE OF SMOKE/ELECTRICAL ODOR TO BE THE STATIC INVERTER. REPLACED SAME. OPN CKS NORMAL. NO ODOR NOTED. REPLACED THE FWD EQUIP DET LIGHT ASSY. SYSTEM CKS NORMAL.