What was found
FOUND BY MTC, RT WING LOWER CLOSE OUT PANEL FOR T/E FLAP DAMAGED BETWEEN NR 7 AND 8 TRACK HOUSINGS. REPLACED 4 WIGGLER PLATES AND C-CHANNEL BETWEEN NR 7 AND NR 8 FLAP TRACK HOUSING AND INSTALLED CLOSURE PANEL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND BY MTC, RT WING LOWER CLOSE OUT PANEL FOR T/E FLAP DAMAGED BETWEEN NR 7 AND 8 TRACK HOUSINGS. REPLACED 4 WIGGLER PLATES AND C-CHANNEL BETWEEN NR 7 AND NR 8 FLAP TRACK HOUSING AND INSTALLED CLOSURE PANEL.