What was found
AFTER DEPARTING HNL, FLAPS LOCKED AT 6 DEGS AND EICAS MSG T/E FLAP DISAGREE APPEARED. C/W QRH PROCEDURE AND RAISED FLAPS USING ALTERNATE MODE BUT FLAPS WOULD NOT COME UP BEYOND 2 DEGS. INITIATED AIR TURNBACK TO HNL. LANDED OVERWEIGHT, MTC IN PROGRESS. NO FAULTS ON FSEU. CHECKING OVER TORQUE TRIP INDICATORS. NO HISTORY. FOUND T/E FLAP ROTARY ACTUATORS 2 - 3 - 4 AND 6 OVER TORQUE IND TRIPPED. RESET SAME, ALL OPS NORMAL.