What was found
DURING SHOP INSPECTION, SEVERAL HOLES FOUND. ONE HOLE FOUND 1 DIA, 14 AFT OF SPAR AND 29 FROM O/B EDGE, 1 HOLE FOUND 1 DIA, 27 FROM T/E AND 37 FROM O/B EDGE, 1 HOLE FOUND 1.5 DIA, 14 FROM T/E AND 32 FROM O/B EDGE, AND 1 HOLE FOUND 1 DIA, 21 FROM O/B EDGE AND 25 FROM T/E. REPAIRED AS PER SRM 55-20-01, FOR RT ELEVATOR.