What was found
APPROXIMATELY 6 HOURS AND 50 MINS INTO FLIGHT RIGHT VSI CB POPPED AND RIGHT GEN TRIPPED OFF SIMULTANEOUSLY. A SLIGHT ELECTRICAL SMELL WAS NOTED IN THE FLIGHT STATION. THIS DISSIPATED RAPIDLY. GEN WAS RESET SUCCESSFULLY AS PER THE QRH PROCEDURE. RIGHT VSI CB NOT RESET. VERIFIED ELECTRICAL ODOR FROM RT VSI. REPLACED VSI, RESET CB AND OPS CHECK NORMAL. PERFORMED BITE CHECK OF BPCU RT GEN FAULTS DP TRIP IDG RISE TEMP GEN/FDR MAIN BUS/OVERLAP ZONE. PER FIM24-20-00 CHECK FDRS FOR SHORTS, ALL OK. IDG SERVICED PER PDC. REPLACED RT GCU, RUN UP CHECK NORMAL.