As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ON SHUTDOWN OF LEFT ENG L ENG PRV EICAS AND LEFT BLEED LIGHT ILLUMINATED. CHANGED MEL TO 36-11-08C. PERFORMED MEL PROCEDURES NR 1 ENG PRV. THIS MEL MORE ACTURATELY REFLECTS THE PROBLEM. REPLACED PRVC PER M/M RAN ENG. BLEED AIR OPS NORMAL, REACTIVATE HP VALVE, FAV AIR SUPPLY O/P SWITCH AND T/R. MCO AND PLACARD REMOVED.