What was found
FIRE WARNING HORN SOUNDED/AURALLY ALERTED IMMEDIATELY ON LIFT OFF. NO LIGHTS EICAS MESSAGES O ANY INDICATIONS AT ALL WERE APPARENT. THE HORN SOUNDED UNTIL LANDED AND TAXIED BACK. PULLED J34 AND B18 WARN ELEX CBS. HORN SILENCED WHEN B18 PULLED. LANDING WEIGHT 319.9. NO OVERWEIGHT LANDING. REMOVED AND REPLACED PWR SUPPLY MODULE B AND ENG/CARGO FIRE TEST PANEL. ALL OPS CHK NML. TEST OPS NML FIRE WARNING SHUTS DOWN.