What was found
POSSIBLE AIR CONDITIONING TRANSIENT SMELL AT FL380. DESCENDED TO FL240 TURNED OFF RECIRC FANS, NO FURTHER SMELL. AFTER LANDING FLT ATT REPORT ELECTRICAL SMELL FORM MID GALLEY. UPON INSPECTION FOUND MID GALLEY AFT LOWER OVEN FAN SEIZED. ALSO ELECT SMELL PRESENT IN OVEN FWD OVEN TO MCO AND PLAC PER MEL.