As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
TE FLAP DISAGREE ON GO AROUND. A/C DECLARED EMERGENCY LANDING. TE FLAP SHUTDOWN EICAS MSG WITH FLAPS LOCKED AT 24 DEG. ON ARRIVAL AT GATE, MTC PERFORMED, BITE OF FSPM CARDSALL TEST OK, PSEU BITE IS GO. FLAP TORQUE LIMITERS WERE NOT TRIPPED. ALL T/DONE PER FIM. RESET ALT FLAP SWITCHES AND MSG EXTINGUISHED. RAN FLAPS ALL OP CKS NORMAL. FLAP HANDLE DETENT AND PIN INSP OK.