Service difficulty report · Shutoff Valve · Boeing 767332

Difficulty date
August 3, 2007
Submitted
August 8, 2007
Operation
Air carrier
Aircraft
N185DN
Make and model
Boeing 767332
Aircraft serial
27961
Aircraft time
59,474 hours, 8,933 cycles
Part
Shutoff Valve
Condition
Malfunctioned
Location
Te Flaps
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ON DEPT WHEN RAISING FLAPS FROM 5 TO 1 TE FLAP DISAGREE LIGHT ILLUMINATED FLAPS RAISED OK WITH ALT SYSTEM. DIVERTING TO JFK FOR REPAIRS, T/S PER FIM. FSEU AND FSPM SHOW NO FAULTS. TE PDU NOT BYPASSED. CHECKED ALL FLAP ROTARY ACTUATOR TORQUE LIMIT INDICATORS. NONE TRIPPED. REMOVED AND REPLACED FLAP/SLAT SOV PER AMM ALSO R/RFSEU PER AMM. RAN FLAPS NUMEROUS TIMES. NO MSGS. OK FOR SERVICE.