What was found
ON CLIMBOUT, HAD LEFT BLEED OVERHEAT LIGHT WITH EICAS MSG, RETURNED ATL. AIR SUPPLY BITE FAULTS FAN, AIR VALVE AND FAN AIR TEMP SENSOR. REPLACED FAN AIR VALVE AND FAN AIR TEMP SENSOR. AIR SUPPLY BITE CHECKS GOOD OPERATION NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.