What was found
FOUND DURING INTERNATIONAL CHECK, EMERGENCY LIGHTS FROM 1A/B F/G THROUGH 5A/B F/G INOP. FOUND FUSES BLOWN ON POWER SUPPLY AT 2A/B AND LUMINATOR SHORTED AT SEAT 5A/B. REPLACED POWER SUPPLY AND LUMINATOR. LIGHTS TEST NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND DURING INTERNATIONAL CHECK, EMERGENCY LIGHTS FROM 1A/B F/G THROUGH 5A/B F/G INOP. FOUND FUSES BLOWN ON POWER SUPPLY AT 2A/B AND LUMINATOR SHORTED AT SEAT 5A/B. REPLACED POWER SUPPLY AND LUMINATOR. LIGHTS TEST NORMAL.