As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ON APPROACH INTO SJU RT SHOCK STRUT DOOR FELL OFF. DOOR WAS RECOVERED IN A HOUSE CARPORT, NO PERSONAL INJURIES. UPON INSPECTION FOUND TWO HYD BRAKE LINES DAMAGED. ALSO, THE TRUNNION DOOR WAS DAMAGED. REMOVED SAME, REPLACED DOOR. REPAIRED OTHER DAMAGE.