What was found
IN FLIGHT EICAS MESSAGES C-HYD PRESS AND C-HYD QTY SHOWED .07RF, LATER WENT TO ZERO. CENTER ELEC 1 AND 2 PRESS AND CENTER AIR PRESS LIGHTS ILLUMINATED. C/W QRH PROCEDURE. INSPECTED AND FOUND HYD LINE COMING FROM RT BRAKE METERING VALVE TO T FITTING CRACKED. REPLACED LINE. SERVICED CTR HYD TO FULL. PERFORMED LEAK CHECK. LEAK CHECKS GOOD.