What was found
DURING CRUISE 37000 FT 1 HR INTO FLT, SMELLED ELECTRICAL SMELL. SHUT OFF UTILITY BUSSES PULLED C/BS U6 U33. F/A REPORTED, WORSE IN LT HAND F/C TURNED OFF LT PACK WHEN PAX IN 14A. REPORTED PUFF OF SMOKE FROM LT FLOOR BOARD GRAY IN COLOR. RECEIVED PRIORITY HANDLING INTO SLC. FOUND BULB BASE SHORTED AT 14B. REBULBED AND REPLACED INOP LIGHT DECODER.