What was found
THE FUSELAGE TO FRAME SHEAR TIE AT STA 1562 LOCATED ON THE FWD SIDE OF THE FRAME BETWEEN STR 38L AND 38R WAS FOUND CORRODED. THE (P/N 150T2102-656) SHEAR TIE WAS REPLACED PER DWG 146T1223.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
THE FUSELAGE TO FRAME SHEAR TIE AT STA 1562 LOCATED ON THE FWD SIDE OF THE FRAME BETWEEN STR 38L AND 38R WAS FOUND CORRODED. THE (P/N 150T2102-656) SHEAR TIE WAS REPLACED PER DWG 146T1223.