As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLUORESCENT LIGHT ABOVE FLT ATT CREW REST BUNK NR 6 INTERMITTENT OPERATION HOT PLASTIC ODOR AND SCORCHED SPOT AT AFT END OF BUNK. FOUND FLUORESCENT BULB SOCKET BURNT. FWD TO MCO AND PLAC PER MEL 33-21-01. LIGHT DEACTIVATED, CAPPED AND STOWED CANNON PLUG FOR BALLAST.