What was found
AT HMV, FOUND FLOORBEAM CORRODED AT FS 297 RBL 30 TO 36 FWD GALLEY. CLEANED CORROSION, DAMAGE OUT OF LIMITS, CUT AND DRILLED NEW CAP. FABRICATED PARTS PAINTED AND INSTALLED PER SRM 53-21-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT HMV, FOUND FLOORBEAM CORRODED AT FS 297 RBL 30 TO 36 FWD GALLEY. CLEANED CORROSION, DAMAGE OUT OF LIMITS, CUT AND DRILLED NEW CAP. FABRICATED PARTS PAINTED AND INSTALLED PER SRM 53-21-00.