What was found
AT HMV, INSPECTION FOUND CABIN FLOOR BEAM CORROSION AT F.S. 1763 AT RBL 52. REPAIRED BY REPLACING SECTION OF T CAP PER SRM 53-21-00 PG 823.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT HMV, INSPECTION FOUND CABIN FLOOR BEAM CORROSION AT F.S. 1763 AT RBL 52. REPAIRED BY REPLACING SECTION OF T CAP PER SRM 53-21-00 PG 823.