What was found
AT HMV, FOUND FITTING CORRODED, AT I/B SIDE RMLG HOLE 17-20. REAMED HOLES TO .625 INCH, CORROSION REMOVED WITHIN LIMITS. HFEC OF FACE AND HOLES, REOPENED PER PS 900-4-5, CAD PLATED PER PS 900-3-9 NR 4. TURNED BUSHING TO SIZE AND TREATED, INSTALLED BUSHING AND REAMED TO SIZE. OXIDE BLASTED. PRIMED AND PAINTED. PER SRM 57-14-00.