What was found
AT HMV, FOUND FITTING CORRODED, I/B RMLG ACT FITTING FLANGE. MACHINED TO .030 INCH FROM VERTICAL FACE IM\N LOWER AREA. LOCAL BLENDED SMALL AREA. PER SRM 57-14-00 PG 811. CORROSION REMOVED, HFEC OF FITTING, ROTO PEENED PER PS 900-4 NR 5. CAD PLATED PER PS 900-3-9 NR 4. OXIDE BLASTED, PRIMED, AND PAINTED. MFG AND TREATED SHIM. INSTALLED SHIM PER SRM 57-14-00.