What was found
AT HMV FOUND HOLE CORRODED, 1, 2, 3, 5, 6, RMLG ACT FITTING. REAMED TO .688 INCH, CORROSION REMOVED. SPOT FACED NR 3 HOLE 1.750 INCH DIA AND .010 INCH DEEP CORROSION REMOVED. HFIC HOLES AND FACE. ROTO PEENED PER PS 900-4 NR 5. CAD PLATED PER PS 900-3-9 NR 5. HOLES AND SPOT FACE WITHIN SRM 57-14-00 LIMITS. TURNED BUSHING TO SIZE AND TREATED INSTALLED BUSHING AND REAMED TO SIZE OXIDE BLASTED, PRIMED, AND PAINTED. MFG, TREATED, INSTALLED WASHER.