What was found
AT HMV, FOUND HOLES CORRODED, RMLG 11-16 ACT ATTACH FITTING. REAMED HOLES TO .562 INCH, CORROSION REMOVED WITHIN LIMITS PER SRM 57-14-00. HFEC HOLED AND FACE, ROTO PEENED PER PS 900-4 NR 5. CAD PLATED PER PS 900-9 NR 4. TURNED BUSHINGS TO SIZE AND TREATED. INSTALLED BUSHING AND REAMED TO SIZE. OXIDE BLASTED, PRIMED, AND PAINTED.