What was found
AT HMV, FOUND FITTING ON MLG RETRACT ACT CORRODED. REAMED HOLES AND BURNISHED AREA. HEFC OF AREA GOOD. MFG AND PAINTED SHIMS, INSTALLED BUSHINGS C/W ERA 271436-14. WORK DONE PER SRM 57-14-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AT HMV, FOUND FITTING ON MLG RETRACT ACT CORRODED. REAMED HOLES AND BURNISHED AREA. HEFC OF AREA GOOD. MFG AND PAINTED SHIMS, INSTALLED BUSHINGS C/W ERA 271436-14. WORK DONE PER SRM 57-14-00.