What was found
NR 2 ENG IDG DROPPED OFF LINE AT 33000 FT, LOW OIL PRESS ILLUMINATED, TEMP 100, RISE 25. DISCONNECT FAILED, 3G15 C/B POPPED. RESET, DISCONNECT FAILED ON 2ND ATTEMPT, (PMG STILL ON) IDG OIL CLIMBED TO 150 RISE TO 35 DEG. IDG OIL CONTINUED TO RISE IN YELLOW ZONE. NR 2 ENGINE SHUTDOWN. REPLACED IDG.