What was found
DURING LAYOVER, WHILE WORKING DEFERRED ITEM FOR TRIPPED GALLEY POWER BREAKERS, FOUND FWD GALLEY FEEDER WIRES BURNED BELOW FWD CARGO COMPARTMENT FLOOR. WIRES WERE DAMAGED BY RUBBING ON EDGES OF LIGHTNING HOLE BETWEEN PANEL 132CR AND THE CARGO FLOOR. THE CLAMP HOLDING THE WIRES WAS FOUND BROKEN. ALL THREE CABLES WERE FOUND COMPLETELY BURNED THROUGH. WIRE NR 567A8A, 568A8B, 569A8C. DAMAGED SECTIONS OF WIRE WERE REPLACED AND SECURED.