What was found
DURING INSPECTION OF THE LT AND RT WING REAR SPAR UPPER CAP FASTENER HOLES PER EO 7-59089-3 SEVERAL CRACK INDICATIONS WERE FOUND ON THE RT REAR SPAR. ALL NON CRACKED HOLES WERE COLD WORKED. THE AREA WAS THEN REPETITIVELY INSPECTED. ALL COVERED BY PREVIOUS ERA 304992-14. A DECISION WAS MADE TO ACCOMPLISH REAR SPAR MOD DUE TO REPETITIVE INSPECTION REQ. REPAIR PER ERA 331265-14AD WHICH TERMINATES ACTION FOR SI7-71067-12AD.