ON DESCENT, SMOKE ODOR IN CABIN. NR 2 PACK COMPRESSOR DISCHARGE TEMP OFF SCALE HIGH. ACM TEMP 40 DEGREES. REPLACED COMPRESSOR DISCHARGE TEMP SENSOR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ON DESCENT, SMOKE ODOR IN CABIN. NR 2 PACK COMPRESSOR DISCHARGE TEMP OFF SCALE HIGH. ACM TEMP 40 DEGREES. REPLACED COMPRESSOR DISCHARGE TEMP SENSOR.