As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
STRONG ELECTRICAL SMOKE SMELL REPORTED IN AREA OF BC GALLEY ODOR REPORTED BY PAX AND CREW. MID GALLEY A/C AND D/C CIRCUIT BREAKERS PULLED AND COLLARD FOUND CHILLER CYCLING ON AND OFF. CHILLER FWD TO MCO AND PLAC PER MEL 25-22-01. DUE TO CREW REPORTS OF CHILLER SMOKE SMELL INSP GALLEY COMPONENTS, NO OTHER DEFECTS NOTED.