What was found
BAT 6 LOW LIGHTS DURING EMERGENCY LIGHTS TEST AFT SECTION EMERGENCY FLOOR LIGHTS AND SIGNS INOP. FOUND LT DOOR EMERGENCY LIGHT ASSY SHORTED TO GROUND L2-531. REPLACED LIGHT ASSY, OPN NORMAL.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
BAT 6 LOW LIGHTS DURING EMERGENCY LIGHTS TEST AFT SECTION EMERGENCY FLOOR LIGHTS AND SIGNS INOP. FOUND LT DOOR EMERGENCY LIGHT ASSY SHORTED TO GROUND L2-531. REPLACED LIGHT ASSY, OPN NORMAL.