Service difficulty report · Bleed Valve · Doug MD88

Difficulty date
May 16, 2001
Submitted
May 18, 2001
Operation
Air carrier
Aircraft
N913DL
Make and model
Doug MD88
Aircraft serial
49544
Aircraft time
37,168 hours, 31,057 cycles
Part
Bleed Valve
Part number
99193
Part serial
P810
Condition
Leaking
Location
Bleed Air
Stage of operation
CL
How discovered
O
Nature of condition
M
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ON T/O AFTER PASSING 1000 FT AGL TAIL COMPARTMENT TEMP HIGH MESSAGE ILLUMINATED ON AOP. FOLLOWED ABNORMAL PROCEDURE IN POM AND ISLOATED RT PACK OFF AND MSG WENT OUT. MESSAGE RE-ILLUMINATED WITH PWR UP AND CLIMBING THUR 240. REPLACED RIGHT CROSS-BLEED VALVE AND CLAMPS. RAN ENGINE TO TAKEOFF POWER AND CHECKS OK PER PFHB. PRESSURIZED AIRCRAFT, LEAK CK''D DUCTING, OPERATED PACKS AND ALL CKS OK.