What was found
RT MAIN GEAR UNSAFE LIGHT REMAINS ON AFTER GEAR RETRACTION. PERFORMED POM PROCEDURES, LIGHT REMAINS ON. ALSO GOT AUTO-SPOILER FAIL MSG ON AFTER INITIAL GEAR RETRACTION, LANDING GEAR INDICATION. CHECK PROX SENSORS ALL OK. REPLACED RIGHT MAIN GEAR ACTUATOR ASSY, OPS CHECKS OK, NO LEAK DETECTED. REF M/M 32-32-02-2.